Location:Home - Products
Auxiliaries

Click to view big picture
Inquiry    

Auxiliaries

Deaerator, HP heater , LP heater, Condenser, Gland heater, Water filter, Oil filter, Steam strainer, Oil cooler, Extraction valve, Oil tank, Ejector, Two-stage steam jet air ejector,Main safety valve.
Condenser
Condenser Technical   Specification

Model
Cooling
Area
(m2)
Type
Overall
Dimensions
(mm)
Steam
inlet size
(mm)
Water
inlet and
outlet size
(mm)
Cooling
Water Flow
(t/h)
Net Weight
(with no
water)
(kg)
NC14
140
Single-
PassTwo-
Flow
4160x2850x1550
800
250
450-650
3130
NC16
160
3910x2680x1485
700
250
600-800
5012
NC28
280
5000x3395x1670
1100
300
800-1100
6350
NC42
420
Two-
PassTwo-
Flow
4965x3510x2555
1220
400
1200-1800
9640
NC56
560
5090x3850x2805
1100
400
1600-2400
13960
NC100
1000
6125x4305x3660
2000x1350
600
2400-3500
25110
NC125
1250
7291x4315x3844
2000x1350
700
2500-3600
29150
NC125-1
1250
7277x4410x2903
3640x1140
600
2500-3600
27712
NC160
1600
8305x4721x3312
3640x1140
600
2600-4000
34502
NC200
2000
8305x4721x3312
3640x1140
700
4300-6400
37900
NC220
2200
9020x5195x3710
4040x2000
700
4300-6400
37900
NC350
3500
9330x5740x4235
6000x1650
800
7000-10500
61999
 Oil Cooler

Two types: plate-type and smooth tube type.

YL model of oil cooler is smooth tube, and it uses cooling circulating water as the medium to do the heat exchange.

YL model of oil cooler is mainly composed of upper and bottom water tank, shell tube and oil-filled tube. There are in-out water tube, in-out oil tube, water drain tube, oil drain tube, air drain tube and thermometer on the shell.

The cooling water flow is generally two-pass which can be divided into vertical or horizontal. Heat transfer cooling tube can be chosen with stainless steel tube or copper tube as the heat transfer components, which is decided by user's needs.

Double-joint-style oil cooler insures the oil is secure. Double-joint-style oil cooler is composed of two oil coolers with the same cooler area. One is for work and the other is for spare. This makes the units is easy to clean and maintain when running. The two oil coolers can be also used at the same time to avoid the lubricating oil temperature off the specification requirement.

 
Model
Area of
cooling
surface
(m2)
Cooling
oil
capacity
(l/h)
Oil Temperature
(℃)
Water
Temperature
(℃)
Cooling 
Water 
Capacity 
(t/h)
Inlet
Output
YL-12.5
12.5
165
55
45
27/33
25
YL-20
20
240
55
45
27/33
35
YL-32
32
500
55
45
27/33
80
YL-40
40
685
55
45
27/33
102
YL-50
50
740
55
45
27/33
112
YL-60
60
975
55
45
27/33
150
Heater
Heater Technical    Specification
Model NG2 NG5 NG7-1 NG7-2 NG8-1 NG8-2 NG10-1 NG10-2 NG10-3 NG14-1 NG14-2
CoolingM" 20 50 65 65 80 80 100 100 100 140 140
Sealingmethod Flangesealing Flangesealing Flangesealing Selfsealing Flangesealing Selfsealing Flangesealing Selfsealing Flangesealing Flangesealing Selfsealing
Designtemp(℃) Tubing 155 155 155 160 160 160 160 160 180 180 200
Shell 350 350 350 400 350 350 350 350 350 350 350
Designpress(Mpa) Tubing 6 6 6 9.6 6 9.8 6.6 9.6 6 6 9.8
Shell 1 0.7 0.7 0.7 1.5 1.5 1.5 1.3 1.3 1.3 1.3
Note HPStraightTube HPU-shapedTube
Model ND1 ND2 ND4 ND7-1 ND7-2 ND8 ND13-1 ND13-2      
Cooling M2 10 20 40 65 65 80 125 125      
Sealingmethod Flangesealing Flangesealing Flangesealing Flangesealing Flangesealing Flangesealing Flangesealing Flangesealing      
Designtemp(℃) Tubing         150 100 99 150      
Shell         240 200 99 240      
Designpress(Mpa) Tubing 0.6   0.6 0.6 1.2 1.5 1.2 1.2      
Shell 0.2   0.2   0.6 0.3 0.2 0.6      
Note LowPressure      
     