Location:Home - Products
Natural Gas Generator

Click to view big picture
Inquiry    

The fuel of the unit is natural gas, oil field associated gas, LPG, and widely used in regions of oil and gas. The unit can start quickly, be operated easily, with complete set of safety system,  and can be power device and electricity device for oil field and local companies.

The main functions:

1. Drive oil pumping unit

2. Generate power by natural gas 

3. Drive water injector and mixed pumps by separate gas 

4. In gas station, drive compressor or instead of power supply  

5. For hotel, standby power supply 

6. In cool-hot power supply system, improve efficiency and lower the cost  

7. Establish small and medium power plant.

Requirement on gas:

After gas and fluid separation, flitting, pressure stabling.

1. Nature gas inlet pressure: 24KW/40KW/120KW, inlet pressure 30KPa~300KPa; 180KW~500KW inlet pressure 80KPa~300KPa; 600kW inlet pressure 100KPa~300KPa;

2. Firedamp in natural gas volume not less than 70%, sulfur ≤480mg/Nm3, impurity granularity ≤5μm, impurity ≤50mg/Nm3;

3. No Dissociate water in natural gas.

Natural gas generator unit model and main technical parameters:
 
Model
40GF-T
120GF153-T
180GF1-T
250GF1-T
Motor model
4105ZLD
4190D-2B
6190-2B
6190ZL-2B
Generator model
1FC6224-4LA42
1FC6350-6LA42
1F6354-6LA42
1F6356-6LA42
Rated speed (r/min)
1500
1000
1000
1000
Rated capacity (KW)
40
120
180
250
Rated voltage (V)
400
Rated current (A)
72.2
217
325
451
Rated frequency (Hz)
50
Rated power factor (COSφ)
0.8 lagging
Burn gas heat rate (MJ/KW.h)
10.3
12.3
11
Lube oil consumption (g/KW.h)
≤1.4
Heat rate (MJ/KW.h)
≥36%
Steady state speed governing rate Lube oil consumption (%)
≤5
Press adjusting way
AVR atomic adjust
Excitations
Brushless
Phase and connection
3 phase 4 wire
Start up
24V DC start up
Cooling way
Close, cooling fan
Open/close
Overall dimensions L×B×H(mm)
2380
×1156
×1632
2236
×1122
×1655
4648
×1976
×2218
(open)
6400
×2200
×3270
(open)
Weight (Kg)
1450
2820
8010
8800
 
 
Model
300GFI-T
400GF1-T
500GF1-T
600GF1-T
200GF2-T
Motor model
6190ZL-2B
12V190-2A -
12V190ZL-2H
12V190ZL-2J
QN6170ZL
Generator model
1FC6 404-6LA42
1FC6 406-6LA42
1FC6454-6TA42
1FC6 456-6LA42
1F6354-6LA42
Rated speed (r/min)
1000
Rated capacity(KW)
300
400
500
600
200
Rated voltage (V)
400
Rated current (A)
541
721
902
1083
361
Rated frequency (Hz)
50
Rated power factor (COSφ)
0.8 (lagging)
Burn gas heat rate (MJ/KW.h)
≤11
≤13
≤9.8
≤9.5
≤12
Lube oil consumption (g/KW.h)
≤1.4
≤1
Heat rate (MJ/KW.h)
≥36%
Steady state speed governing rate Lube oil consumption (%)
≤5
Press adjusting way
AVR atomic adjust
Excitations
Brushless extraction
Phase and connection
3 phase 4 wire
Start up
24V DC start up
24V DC start up or air motor
Cooling way
Open/Close
Close
Overall dimensions
LXBXH(mm)
4660
×1965
×2212
(open)
5180
×1968
×2232
(open)
5506
×1970
×2910
(open)
5510
×1968
×2696
(open)
3900
×1265
×1900
Weight (Kg)
7990
12000
125050
12480
 
 
 
Copyright © 2006-2010 QnPower.Com.Cn ALL RIGHTS RESERVED Tel:+86-536-3291833