You are here:Home > Industrial Steam Turbine
Air-cooled steam turbine can be designed according to customer's needs.
Characteristics:
The maximum inlet steam pressure: 10.5Mpa;
The maximum inlet steam temperature: 535℃;
The maximum capacity: 200MW;
The exhaust steam can be used for other heat supply purpose;
It can be used for power generating or driving other running equipment with constant speed;
Customization service;
Remote monitoring and diagnose service;
Parameter:
NO.
|
Model
|
Capacity
(MW) |
Inlet
|
Exhaust
Pressure (Mpa) |
Speed
(r/min) |
|
Pressure
(MPa) |
Temp
(℃) |
|||||
1
|
B0.4~B1.6
|
0.4~1.6
|
1.2~4
|
300~470
|
0.2~1.27
|
6500
|
2
|
B0.8~B1.6
|
0.8~1.6
|
3.5~6.5
|
270~435
|
1.1~2.5
|
6500
|
3
|
B1.6~B3
|
1.6~3
|
2.3~4.9
|
300~470
|
0.2~2.5
|
5600
|
4
|
B3~B8
|
3~8
|
2.3~4.9
|
300~470
|
0.2~2.5
|
3000
|
5
|
B3~B8
|
3~8
|
3.5~6.5
|
390~470
|
0.5~2.5
|
3000
|
6
|
B3~B8
|
3~8
|
4.9~10
|
435~535
|
0.5~5
|
3000
|
7
|
B9~B12
|
9~12
|
2.3~5
|
390~470
|
0.2~2.5
|
3000
|
8
|
B9~B12
|
9~12
|
4.9~10
|
435~535
|
0.5~5
|
3000
|
9
|
B12~B18
|
12~18
|
2.3~5
|
390~470
|
0.2~2.5
|
3000
|
10
|
B12~B18
|
12~18
|
4.9~10
|
435~535
|
0.5~5
|
3000
|
11
|
B20~B30
|
20~30
|
2.3~5
|
390~470
|
0.2~2.5
|
3000
|
12
|
B20~B30
|
20~30
|
4.9~10
|
435~535
|
0.5~5
|
3000
|
13
|
B40~B50
|
40~50
|
4.9~10
|
435~535
|
0.5~5
|